Steam accelerated aging test chamber

  • Hot Line:18322499311


高低溫低氣壓試驗.jpg


The Steam accelerated aging test chamber is one of the commonly used equipment in various aging experiments, suitable for testing the performance indicators of electronic instruments, materials, electricians, vehicles, metals, electronic products, and various electronic components in High temperature and high pressure environments And for quality management purposes.


Performance indicators and composition of each system


model



Sample limitations


This testing equipment prohibits the testing of samples containing flammable, explosive, and volatile substances; Tests for storing samples of corrosive substances, tests for storing organisms, tests for storing samples of strong electromagnetic emission sources, and storage.


to configure


1. Test box, 1 unit


2. Oxygen/nitrogen, 5 bottles each


3. Test computer, 1 set


4. Testing software, 1 set


Volume, weight, and size


Nominal internal volume


0.0628m3


Effective size of inner box


Φ400×D 500(mm)


Exterior space


Approximately 1700 × 2100 × 2000 (mm) W × H × D


weight


660㎏


Work noise


Measure at a distance of 1 meter from the machine and 1.2 meters from the ground in front of the machine, with a value of ≤ 70db


Power, current, and power supply


maximum power


6KW


Maximum current


1*


 


Power supply conditions


And power supply


 


AC220V single-phase R, N+protective grounding; The allowable voltage fluctuation range is 10%;


The allowable frequency fluctuation range is 50 ± 0.5HZ; TN-S power supply or TT power supply


The grounding resistance of the protective grounding wire is less than 4 Ω


Require users to configure corresponding capacity air or power switches for the equipment at the installation site, and this switch must be independently controlled. When placing powered samples in the equipment use box, please use an external power source for the sample power supply and do not directly use the local power supply;


performance index 


Environmental conditions for use


The value measured under the conditions of an ambient temperature of+25 ℃, relative humidity ≤ 85%, and no sample in the test chamber.


The amount of steam generated


Can be controlled at (5+0.5) L/min;


Timing device


999min, error ± 1s


Nitrogen flow rate


The controller can control the flow rate at (500+250) mL/min


Gas mixture


It can control the mixing of 80% nitrogen and 20% oxygen, and the flow rate can be controlled at (100+10) ml/min;


Fully automated testing


The test chamber can perform fully automatic testing in accordance with clause 9.4 of GB/T 4677-2002, automatically controlling various valves or flow meters, timing, etc


Sample fixture


It can rotate inside the test chamber, with an adjustable speed of 5 to 50 revolutions per minute; The sample fixture can clamp the sample in a vertical position, ensuring a distance of about 6mm between the samples and even distribution of steam or gas on the sample. The fixture and rotating rod in the test chamber are made of materials such as stainless steel or polytetrafluoroethylene that do not retain test gases


Pure oxygen/nitrogen


8L/bottle. 5 bottles each


Note: The above performance indicators are measured under the conditions of an ambient temperature of+25 ℃, relative humidity ≤ 85%, and no sample.


Execution standards and testing meet the conditions


1. GB/T 2423.40-2013 Environmental testing Part 2: Test Methods Test Cx: Unsaturated High Pressure Steam Constant Damp Heat;


2. GB/T 41203-2021 Accelerated Aging Test Method for Photovoltaic Module Packaging Materials;


3. GB/T 5170.2-2017 Environmental testing equipment for electrical and electronic products - Inspection methods - Temperature testing equipment;


4 IEC60068-2-66 Environmental testing-Part   2:Test methods-Test Cx: Damp heat, steady state (unsaturated pressurized   vapour)。


structure characteristics


Box Structure 


Inner box material: SUS316 stainless steel 1.5mm thick


Outer box material: 304 # stainless steel 1.0mm thick or (cold-rolled steel plate 1.2mm thick baked paint treatment, optional)


Insulation material: Polyurethane foam adhesive 100mm thick


The control box and test box are integrated, with a left and right structure


Install mobile casters and positioning foot cups at the bottom of the box


The test box door adopts a rotating handle snap lock, which is safe and reliable.


Door and lock system


The test box door should adopt a sliding design, with a motor drive system with a tray, and automatically approach. The heat dissipation should adopt a side heat dissipation design to avoid direct contact with the human body and high temperature burns.


turntable


SUS316 # stainless steel is punched and bent into a mesh shape, making it easy to use. According to the drawings.


The motor shaft of the rotary table is sealed with an O-ring.


 


Distribution control cabinet


Main power circuit breaker, controller, distribution board, cooling fan, over temperature protector.


Water replenishment system


Self made PVC enlarged water tank, water pump lifting automatic water supply.


electric control system 


controller


Weisi customized controller, true color LCD display, capacitive touch


Touch screen controller with high control accuracy and responsiveness


Advantages such as sensitivity and ease of use.


 


 


 


Test computer


Desktop computer (i7 6700, 16g storage, SSD hard drive 1TB, 24 inch screen), color printer


Screen display


1) It can display the remaining time and accumulated running time of the current execution function.


2) The fault prompt screen is displayed.


Setting method


English interface, button based input. You can choose between program mode or fixed value mode.


Equipment working mode


Saturated, unsaturated, and control mode switching (automatically adjusted according to set conditions), with 3 working mode switching (automatically adjusted according to set conditions)


Program settings


The number of programs that can be set is no less than 100 experimental modes


Recorder


Automatically record parameters such as temperature, gas flow rate, and time during the testing process, and form a testing curve


Communication and Data Processing


1) It has a USB interface for direct copying and recording, including historical curves, historical data, etc., which can be directly copied to the computer for viewing, analysis, and storage.


2) The equipment is equipped with a monitoring computer that can be directly connected to the computer through a local area network or machine to monitor the operation of the machine and remotely control the machine.


Display resolution


Temperature: 0.1 ℃


control mode 


P. I. D Calculus Time Plus SSR Module Control Heating Output


Timing method


Temperature deviation timing/startup timing (optional)


timer


Can be set to switch between seconds, minutes, 10 minutes, hours, and 10 hours, with a maximum timing of 9999 X 10 hours


Supplementary functions


(Standard configuration)


Fault alarm and cause, processing prompt function


A fail-safe mechanism 


Upper and lower temperature protection function


temperature measurement 


PT100 platinum resistor


Safety protection device


Test box


1) Equipped with pressure overpressure protection and temperature over limit alarm protection functions.


2) Equipped with humidification limit temperature power-off protection and water shortage protection functions.


3) Equipped with leakage protection, heating, humidification, dry burning protection, overload and short circuit protection, and power-off protection functions.


4) Equipped with emergency pressure relief function and manual door opening function.


5) Equipped with a prompt function if the box door is not tightly closed.


6) Equipped with power-off program memory, it automatically starts and continues to execute program functions after power restoration.


7) The equipment complies with relevant national security management regulations.


Power Supply


Leakage protection, overload and short circuit protection


Other safety measures


The parts of the machine that can cause harm to the human body should be clearly labeled with warning signs on the equipment;


The professional operation section has clear warning signs on the equipment, and the special section has clear operation steps.


The main control console for equipment operation includes manual switches, buzzer stop switches, automatic start and stop switches, emergency stop switches, etc.


Various safety signs should be prominently posted in prominent locations; The equipment is well grounded and there are no short circuits, open circuits, or damaged wires.



 





Recommended products

主站蜘蛛池模板: 性动态图av无码专区| 日本真人做爰免费的视频| 67194熟妇在线观看线路1| 欧美老人巨大xxxx做受视频| 中文无码人妻有码人妻中文字幕| 巨胸美乳无码人妻视频| 免费网站看sm调教视频| 在线 无码 中文字幕 强 乱| 国产熟妇午夜精品aaa| 国产女人高潮抽搐喷水免费视频 | 国内永久福利在线视频图片| 国产欧美一区二区三区在线看| 精品日韩亚洲欧美高清a| 四川丰满肥嫩肥BBBBB| 国产做a爱片久久毛片a片| 日韩精品视频一区二区三区| 蜜臀av无码一区二区三区| 两性午夜刺激性视频| 白丝爆浆18禁一区二区三区| 午夜成人1000部免费视频| 国产av无码久久精品| 亚洲精品久久久久69影院 | 78午夜福利视频| 无码少妇一区二区三区| 狠狠躁夜夜躁人人爽天天bl | 国产av电影区二区三区曰曰骚网| 成在人线无码aⅴ免费视频| 免费观看又污又黄的网站| 国产精品亚洲精品久久精品 | 天堂在线www天堂中文在线| 国产在线乱子伦一区二区| 麻豆精品秘?一区二区三区| 欧美精品久久96人妻无码| 中文字幕丰满伦子无码ab| 大学生疯狂高潮呻吟免费视频| 欧美亚洲国产第一精品久久| 性色av免费网站| 亚洲精品一卡2卡3卡4卡乱码| 欧美日韩国产图片区一区| 国内精品久久久久影院中文字幕| 羞羞影院午夜男女爽爽|